What we design.
We produce structural plans for shingle, tile, metal, and low-slope assemblies. Designs reference the governing code (IBC/IRC/FBC with local amendments) and ASCE 7 wind loads, plus applicable NOA/ESR product approvals and manufacturer requirements.
Who orders plan sets.
Plan sets are for roofing contractors who hit a permit wall: the AHJ wants structural drawings, or a reviewer rejected the roof plans for missing details. A plan set gives the reviewer what they asked for and gives the crew a buildable set.
- Roofing contractors doing re-roofs, recovers, tile resets and repairs that need engineered details
- Contractors replacing or adding skylights, curbs and roof openings
- Property managers and owners whose roof scope needs stamped structural drawings
If the question is about a roof that is already designed or built, a code compliance letter may be the better fit.
Standards & acceptance.
All plans are prepared under responsible charge by a licensed Professional Engineer and cite governing codes and local amendments. We favor the simplest compliant solution, align with manufacturer instructions, and avoid over-design that inflates cost. Our scope is structural; architectural/MEP items are by others.

Codes and approvals.
Every plan set names the code it is built on. In Florida that is the Florida Building Code (FBC) with local amendments. The 8th Edition (2023) is in effect through December 30, 2026, and the 9th Edition (2026) is scheduled to take effect on December 31, 2026. The edition is tied to the permit, so the set states which one it uses.
Wind loads follow ASCE 7 as the code adopts it. Where a product has a Florida Product Approval, Miami-Dade NOA or an ESR report, the plans cite it and follow the manufacturer instructions that come with it. In the High-Velocity Hurricane Zone (Miami-Dade and Broward), stricter wind and roofing requirements apply and roofing products are approved by NOA.
On a re-roof in Florida, the roof section being replaced and the age of the existing roof can decide how much of it has to meet current code. We cover that on the code compliance page. Outside Florida, the plans cite the IBC or IRC edition the jurisdiction has adopted.
From request to stamped set.
Request
Send the project address, the AHJ, the roof assembly and any reviewer comments.
Scope
We confirm what the plan set covers, the licensing for the project location, and a realistic schedule.
Design
A licensed Professional Engineer prepares the structural details under responsible charge.
Deliver
You get a stamped PDF. Wet-signed originals and CAD (DWG) exports are available on request.
Permit problems a plan set solves.
These are the situations that usually trigger a plan set request.
Revisions & addenda.
One targeted response to standard reviewer comments is included. Substantive scope changes, new product swaps, or field-condition deviations may require a priced revision.
Deliverables & what we need.
Deliverable is a stamped PDF; wet-signed originals and CAD (DWG) exports are available on request. We support multiple jurisdictions and continue to expand. Tell us the project location and any submittal deadline, and we'll confirm licensing coverage and timing based on scope and verification needs.
- Project address and AHJ
- Roof area and assembly type
- Photos of framing/attic (if accessible), perimeters, and penetrations
- Any existing plans or truss layouts
- Desired products: deck, underlayment, edge metal/tile/metal system
- Known redlines or AHJ guidance
- Contact info for the site lead
Plan set FAQs.
A stamped set of drawings and notes that show the structural side of a roofing job: framing, deck attachment, uplift fastening, edge metal and parapet details, and repairs. It is prepared under the responsible charge of a licensed Professional Engineer and submitted with a permit application.
Roofing contractors who need permit-ready structural drawings for shingle, tile, metal and low-slope roofs. Property managers and owners can order them as well. Architectural and MEP items are by others. Our scope is structural.
The governing building code for the project, which in Florida is the Florida Building Code with local amendments, and in other states the IBC or IRC as adopted there. Plans use ASCE 7 wind loads and cite applicable product approvals such as Florida NOAs and ESR reports, along with manufacturer requirements.
It depends on the scope and what has to be verified, so we confirm a realistic schedule when we scope the job. Tell us the project location and any submittal deadline when you request.
One targeted response to standard reviewer comments is included. Substantive scope changes, new product swaps or field-condition deviations may require a priced revision.
Complex structural plan sets are engineered by our parent firm, SunSmart Engineering, which also handles solar, pool and enclosure, and building envelope engineering. RoofLetters focuses on roofing structural scopes.
We support multiple jurisdictions and continue to expand. Tell us the project location and we confirm licensing coverage before work starts. Whether an AHJ accepts a plan set is up to the AHJ, and we cannot promise an outcome.
More from RoofLetters.
Backed by SunSmart Engineering.
Complex structural plan sets are engineered by our parent firm, SunSmart Engineering (COA35170) in Lake Mary, FL. Their licensed team handles broader structural, solar, and building envelope engineering across Florida and beyond, giving every RoofLetters plan set the same code-forward rigor. Visit their site to explore full engineering services.
